Window fault diagnosis
uPVC Window Hinge Draught: Why a Gap Appears and What to Check
A hinge-side draught can point to alignment, hardware or seal-compression issues. The location and behaviour of the gap matter more than a quick attempt to cover it.
The short answer: a draught beside the hinges of an opening uPVC casement can occur when the sash is not being drawn evenly against its weather seal. Worn or unsuitable friction stays, movement in the sash, loose fixings or a damaged gasket can produce similar symptoms. First identify the exact gap and record how the window opens, closes and locks; do not assume that adding sealant or turning an unfamiliar screw is the right repair.
This guide is for an opening casement window where cold air seems to enter near the hinged edge. It is not a set of universal adjustment instructions. uPVC window systems use different profiles, stays, restrictors, locking components and gasket arrangements, and a repair that is suitable for one product may be wrong for another.
The aim is to help you distinguish a hinge-side closing problem from a trickle vent, drainage opening, failed perimeter seal or condensation issue. That gives a window professional clearer evidence and reduces the risk of covering a feature that was designed to remain open.
Start by locating the gap, not naming the fault
A casement has an opening sash, a fixed outer frame, weather gaskets, locking points and hinges or friction stays. Air felt near one corner does not prove which component is responsible. Air can travel behind a trim or along the reveal before it becomes noticeable indoors.
Close and lock the window normally. From the room side, note whether the draught follows the opening joint between sash and frame, comes through a background ventilator, or appears around the fixed frame where it meets the wall. Do not use a flame to trace it. A lightweight strip of tissue can show air movement without bringing a naked flame near curtains, finishes or plastic components.
Hinge side, lock side and frame perimeter are different
A gap along the hinge side may involve the way the stay brings the sash into its closed position. A gap along the lock side may instead relate to locking engagement or compression. Air around the outside of the fixed frame points towards the junction with the wall or its sealant, not automatically towards the opening hardware.
A visible slot at the top of the frame may be a trickle vent. It should not be taped over as a draught repair. The Energy Saving Trust’s draught-proofing guidance advises keeping ventilation in mind, because intentional ventilation and uncontrolled leakage do different jobs. If the vent itself is dusty or stiff, use the separate trickle vent cleaning guide.

Why a hinge-side gap can appear
Many outward-opening uPVC casements use friction stays: linked metal arms that guide and support the sash while providing resistance when it is open. The precise hardware depends on window type, sash size, weight, opening direction, fire-escape function and any restrictor. A component that looks similar is not necessarily an appropriate replacement.
The sash is not closing squarely
If the opening sash has moved relative to the outer frame, one corner may meet the gasket before another. Clues include a new rubbing mark, a handle that has become harder to operate, or an uneven gap when the window is closed. The cause still needs inspection: movement may involve the glazing, hardware, fixings or frame rather than one simple adjustment.
The friction stay is worn, damaged or no longer engaging correctly
A friction stay helps control the sash and, on suitable designs, helps bring it towards the gasket as it closes. ERA’s published information for its Horizon standard friction stay describes a pointed sash arm and nylon end cap used to support gasket compression and smooth engagement. Wear, distortion, corrosion, damage or an incorrect stay can therefore affect closing behaviour.
The Glass and Glazing Federation’s glazing manual also notes that damaged hinges, catches or stays can induce frame distortion and make draught or weather seals ineffective. That is why replacing a gasket without checking the hardware may fail to deal with the cause.
The weather gasket is not providing even compression
A gasket can be displaced, split, hardened, painted over or locally flattened. It can also appear to be the problem when the sash simply is not reaching it. Avoid forcing an extra self-adhesive strip into the opening joint before the original profile and closing geometry have been identified. A strip that is too thick can prevent closing or place extra load on the handle and locking mechanism.
The draught is beside the frame, not through the opening joint
Cracked or missing sealant at the frame-to-wall junction can admit air, but an internal symptom does not show the whole junction. Water staining, movement, a loose trim or an external gap needs a building-fabric assessment rather than a hardware-only repair. Do not bridge drainage routes or apply sealant over a gap whose purpose is uncertain.
Safe checks that improve the diagnosis
These checks are observational. Keep your weight on the floor, use safe access and do not lean out. Stop if the sash feels loose, unusually heavy or unstable.
- Compare closed gaps. View the window from inside and compare the top, bottom, hinge and lock sides. Record where the joint looks wider or the gasket is visible.
- Open it once, gently. Listen for scraping and look for fresh contact marks. Do not repeatedly force a stiff handle or sash.
- Inspect accessible hardware visually. Look for obvious corrosion, a bent arm, loose-looking fixings, a displaced plastic end piece or debris in the track. Do not loosen screws simply to see what moves.
- Check the gasket condition. Note splits, sections pulled from the groove, paint contamination or a visibly flattened area. Do not cut or stretch it.
- Check the result when locked normally. Record whether the draught changes, whether the handle reaches its usual position and whether the sash still opens freely afterwards.
| What you observe | Inspection area to mention | Why it matters |
|---|---|---|
| Gap mainly at a hinge-side corner | Stay engagement, sash alignment and gasket contact | One component can affect how evenly the sash closes. |
| Sash scrapes before the handle is used | Alignment, glazing support and hardware condition | Forcing the window may increase damage. |
| Handle is stiff but the hinge side looks even | Locking points, keeps and overall alignment | This is not automatically a hinge fault. |
| Air is felt around fixed-frame trim | Frame-to-wall perimeter and external seal | The opening hardware may be unrelated. |
| Slot is part of a trickle ventilator | Vent operation and room ventilation | It is an intentional airflow path, not a random gap. |
Leave safety-critical hardware alone. A restrictor may limit how far a window opens, and an egress window may form part of an escape arrangement. Do not remove, bypass or substitute hardware without confirming the window’s function and the correct product specification.
Why a generic “tighten the hinge” video may be misleading
The friction adjustment that controls how readily a sash stays open is not necessarily an adjustment for closing alignment or gasket compression. Turning the wrong screw, moving a stay in its fixing channel or over-tightening a component can create a new operating problem. Manufacturer instructions and the exact hardware reference should guide any adjustment or replacement.
Likewise, silicone spray, oil and cleaning products are not interchangeable. Use only maintenance products permitted by the window or hardware manufacturer, keeping substances away from surfaces they may damage. If product identity is unknown, record the markings and obtain advice first.
Draught, condensation and water ingress need separate evidence
A draught is moving air. Condensation is moisture formed when air reaches a surface at or below its dew point. Water ingress is rainwater passing where it should not. One window can show more than one symptom, but solving one does not automatically solve the others.
If glass is wet, establish which surface is affected before linking it to the hinge gap. Moisture between sealed panes points towards the insulating glass unit, while room-side moisture also depends on indoor humidity, surface temperature and ventilation. A photograph taken before wiping the glass can help. AEG’s double-glazing condensation guide explains the different locations.

Prepare a repair enquiry that is easy to assess
A clear report helps the contractor bring suitable hardware and avoids treating every draught as a full-window replacement. Include the window’s location, approximate age if known, opening style and whether the problem is new or longstanding.
Useful evidence includes:
- A full photograph of the closed window from inside.
- Close photographs of the upper and lower hinge-side corners.
- A photograph of the accessible stay and any stamped manufacturer or size marking.
- A short note describing where tissue movement was observed.
- Whether the sash rubs, the handle is stiff or the lock does not engage normally.
- Any visible gasket damage, frame movement, water staining or perimeter-seal failure.
- Whether the window has a restrictor or is intended as an emergency escape window.
Do not describe the answer as certain before inspection. “There is a visible upper hinge-side gap and the sash has started rubbing at the lower lock corner” is more useful than “the hinges need tightening”.
Repair the component or assess the wider window?
A clearly identified failed stay or gasket may be repairable, subject to correct parts and the condition of the rest of the window. A distorted frame, repeated hardware failure, failed sealed units, widespread perimeter defects or several poorly operating openings may justify a broader assessment. The decision should consider safe operation, weather performance, ventilation and compatibility, rather than draught sensation alone.
If work extends beyond one component, AEG’s window and building works service covers glazing and associated property improvements.
Frequently asked questions
Can I seal a hinge-side gap with silicone?
Not before the gap has been identified. Silicone across an opening joint can stop the sash operating, while sealant in the wrong place can obstruct drainage. Perimeter sealant between a fixed frame and wall is a different detail from the moving sash-to-frame joint.
Does a draught always mean the friction stays need replacing?
No. Alignment, gasket condition, locking engagement and the frame-to-wall junction can produce similar symptoms. The location and operating behaviour should be checked together.
Can I fit a thicker gasket to make the window tighter?
A thicker gasket is not automatically better. The profile must fit the groove and allow the hardware to operate without excessive force. Identify the original system or obtain a compatible recommendation.
Should I block a trickle vent if the room feels cold?
No. A trickle vent is an intentional part of the ventilation arrangement. Check that it is clean and operating as designed, and investigate uncontrolled gaps separately.
When should I stop using the window?
Stop forcing it and seek help if the sash feels loose or unstable, hardware is visibly detached or bent, the handle will not secure the window, or opening it could create a fall or security risk.
Need the window and surrounding work assessed?
AEG Construction can consider glazing and associated building improvements as part of the wider property fabric, helping separate a local hardware symptom from work needed at the frame or reveal.
Explore window and building worksTechnical guidance checked on 13 November 2026. Product-specific instructions and a competent inspection take priority over general guidance.