Heat pump controls explained

Heat Pump Weather Compensation: What the Heating Curve Does

How an outdoor sensor, a heating curve and the flow temperature work together — plus the signs that settings may need an installer’s attention.

Air source heat pump outdoor unit installed beside a brick house

The short answer: weather compensation changes the water temperature sent to radiators or underfloor heating as outdoor conditions change. Colder weather generally calls for warmer water; milder weather calls for cooler water. The heating curve is the rule the controller follows.

A heat pump can be comfortably heating a home even when the radiators do not feel as hot as they did with a boiler. That is often intentional. Instead of delivering short bursts of very hot water, a well-designed heat pump system can run for longer at the lowest flow temperature that keeps the rooms comfortable.

Weather compensation helps it do this automatically. This guide is for homeowners, landlords and residents who want to understand the control principle, recognise useful symptoms and have a better conversation with their installer. It is not a set of brand-specific programming instructions: control names, menus and safe adjustment methods vary.

What heat pump weather compensation means

The controller receives an outdoor-temperature reading. Depending on the equipment, the sensor may be built into the outdoor unit or fitted separately to the building. The control then calculates a suitable heating-water flow temperature from the configured curve.

1. Read outdoorsThe system measures the outside condition using its temperature sensor.
2. Follow the curveThe controller determines a target flow temperature for those conditions.
3. Supply heat steadilyThe heat pump and emitters work together to meet the building’s heat demand.

The principle matters because a building normally loses less heat on a mild day than on a cold day. Sending the same high-temperature water through the system in every condition can cause rooms to overshoot their target and the heat pump to start and stop more than necessary. The Energy Saving Trust heat pump installer toolkit explains that reducing flow temperature as the weather becomes milder can help a heat pump run more steadily.

Weather compensation is about space heating. Domestic hot water is a separate control task, commonly with its own schedule and target. Changing a room-heating curve should not be treated as a way to alter stored hot-water hygiene settings.

Weather compensation is not a weather forecast

The controller is responding to a temperature reading, not deciding whether it will rain next week. Nor does the outside sensor directly tell the controller how warm every room feels. Solar gain, wind exposure, occupancy, cooking and open doors can all change indoor conditions without being fully represented by one outdoor reading.

Some systems add room influence or load compensation, using an indoor measurement as well. Others rely mainly on the outdoor curve and the heat emitters’ ability to match the calculated room-by-room heat loss. The correct arrangement depends on the design and the manufacturer’s control strategy.

How the heating curve works

Imagine a graph with outdoor temperature along one axis and heating-water flow temperature along the other. The curve links the two. Its cold-weather end must provide enough heat for the home in the design conditions, while its mild-weather end should avoid supplying unnecessarily warm water.

Controls describe this relationship in different ways. A screen may show a numbered curve, two end points, a slope, an offset or a simple warmer/cooler adjustment. Those labels are not interchangeable between manufacturers. A curve number copied from another property may produce a very different flow temperature on another controller.

Term What it usually describes Why it matters
Slope or gradient How strongly the target flow temperature rises as outdoor temperature falls. It influences cold-weather heat delivery.
Offset or shift A movement of the curve up or down across a range of conditions. It may correct a consistent tendency to run too warm or too cool.
Maximum flow limit An upper boundary set by the design or commissioning controls. It protects the intended operating strategy and must not be guessed.
Room influence An indoor-temperature input used alongside the outdoor reading. Its effect depends on sensor position and the control logic.

A heating curve is therefore not a promise that one exact radiator temperature will be maintained at all times. The heat pump may also modulate its output, pause for hot-water production or briefly enter defrost in suitable weather. The target shown on a controller and the temperature observed at a particular pipe may differ while the system is responding.

Wall-mounted digital thermostat showing the room temperature
A room control can provide comfort information, but its exact role in weather compensation depends on the system design. Photograph by Dan LeFebvre, Unsplash; uploaded to AEG’s Media Library.

Why lower is not automatically better

Lower flow temperatures can support efficient operation, but only while the emitters can release enough heat to maintain comfort. Reducing a curve below the building’s needs does not improve a cold home. It can produce long periods of operation without achieving the intended room temperature.

The useful goal is not the lowest number visible in a menu. It is the lowest appropriate flow-temperature pattern that works with the property’s heat loss, radiators or underfloor heating, hydraulic arrangement and comfort requirements.

Signs the heating curve may need reviewing

One chilly room or one warm afternoon does not prove that the curve is wrong. First note whether the issue is consistent, how it relates to outdoor temperature and whether it affects the whole property or only one area.

Pattern observed What it could suggest What else to check
Most rooms are too warm in mild and cold weather The overall curve or offset may be higher than needed. Room targets, schedules, room influence and sensor readings.
Most rooms are comfortable in mild weather but too cool when it becomes colder The cold-weather part or slope may need review. Emitter sizing, available flow, system balancing and building heat loss.
Most rooms are too warm only when the weather is mild The mild-weather end of the curve or minimum flow setting may need attention. Whether the heat pump is cycling and whether room controls are creating conflicting demand.
One room is cold while others are comfortable This is less likely to be solved by raising the whole curve. Radiator size, valves, balancing, air in the emitter, furniture or curtains restricting heat output.
The property warms, overshoots, cools and repeats The system may be delivering heat too aggressively or controls may be interacting poorly. Schedules, thermostat location, zoning, minimum output and hydraulic design.

These are diagnostic clues, not remote diagnoses. For example, a cold room might have an undersized radiator, a closed valve or a higher heat loss than the original design assumed. Increasing the whole heating curve could make every other room too warm while leaving the local cause unresolved.

Avoid rapid or undocumented changes. Do not enter installer or service menus unless the responsible professional has explicitly instructed you. Keep the handover settings, manufacturer instructions and any change record. If an approved adjustment is made, change one thing at a time and assess it over suitable weather rather than repeatedly turning several controls.

The Energy Saving Trust’s current homeowner guidance says the installer should set the heating curve and leave information explaining the common settings. It recommends getting a competent installer to check the system if the controls are unclear or the documentation is missing. See The most efficient way to run a heat pump.

The curve cannot compensate for every system problem

Weather compensation is only one part of a heat pump installation. The controller can request a suitable water temperature, but it cannot make a small radiator release more heat than its surface area allows. Nor can it correct restricted pipework, trapped air, an incorrectly positioned sensor or a poorly balanced circuit.

Heat loss and emitter sizing

Each room has a heat demand in the design conditions. Radiators or underfloor heating must be selected to deliver that demand at the intended water temperatures. If the emitters were sized around a higher temperature than the commissioned heat pump strategy, the curve may be raised to mask the shortfall, which can undermine the intended operation.

Hydraulic balance and water flow

The heating water must reach the emitters in the right proportions. A room that receives too little flow may remain cool even when the heat pump is producing an appropriate target temperature. Conversely, a nearby emitter receiving excessive flow can warm quickly and influence a room sensor before distant rooms are comfortable.

Building fabric and later alterations

Insulation, airtightness, window performance and ventilation affect the building’s heat loss. After meaningful fabric improvements, the home may require less heat, so a review of controls can be sensible. Extensions, changed emitters, new floor coverings over underfloor heating or altered room use can also affect the original assumptions.

Panel radiator installed beneath a window in a finished room
Emitter size, placement and system balance all influence whether a low-temperature heating system can maintain comfort. Image from AEG’s heat pump project.

This whole-system relationship is why AEG’s heating upgrade roadmap separates diagnosis and fabric decisions from equipment selection. A heat pump control should be commissioned for the property and its emitters, not treated as an isolated gadget.

What to ask at handover or servicing

A useful handover makes the control strategy understandable without expecting the resident to become a heating engineer. Ask the installer to demonstrate the normal user controls and identify which settings should be left to a service engineer.

  • Where is the outdoor-temperature sensor, and is it integrated or separately mounted?
  • Which screen shows the current outdoor reading and target flow temperature?
  • How is the heating curve represented on this particular controller?
  • Does the system use room influence, and where is the relevant indoor sensor?
  • What heating schedule and setback have been commissioned?
  • Which rooms are most useful for checking comfort after an approved adjustment?
  • What settings were recorded at commissioning, and where is that record kept?
  • Who should be contacted if the home is consistently too warm, too cool or the heat pump cycles frequently?

If you have moved into a property with a heat pump, gather the model information, manuals, commissioning records and service history before changing settings. Photograph the existing user screens so that the starting point is recorded. Report missing documentation to the landlord, housing provider or maintenance contact where applicable.

A simple observation log

When performance is being reviewed, record the date, approximate outdoor conditions, room target, actual room temperature and whether the problem affects the whole home. Also note hot-water periods, recent control changes and any fault message. A short consistent log is usually more useful than isolated screenshots taken from different menus.

For concerns involving loss of heating, repeated faults, electrical smells, leaking water or unsafe access, do not wait to complete a long log. Follow the installer’s or manufacturer’s support process promptly, and treat immediate hazards as urgent.

Heat pump weather compensation FAQs

Should my radiators feel hot with weather compensation?

Not necessarily. They may feel warm rather than hot, particularly in milder weather, because the controller is aiming to match the building’s heat demand with a lower flow temperature. Comfort and steady room temperature matter more than comparing the radiator surface with a former boiler system.

Is a heating curve the same as a thermostat setting?

No. The room target describes the indoor comfort aim. The heating curve links outdoor temperature to a heating-water target. Some controls allow the indoor sensor to influence the curve, but the two settings still have different jobs.

Can I copy a heating curve from another heat pump owner?

No universal curve suits every home. The building heat loss, emitter sizes, control brand and commissioning design can all differ. Use the setting recorded for your system and seek model-specific advice.

Does weather compensation control hot water?

The heating curve normally relates to space heating. Stored domestic hot water has separate targets, schedules and safety considerations. Do not change hot-water settings as though they were part of the weather curve.

When should an installer review the settings?

Ask for a review when the home is consistently too warm or too cool across changing weather, the heat pump cycles repeatedly, controls or documentation are unclear, or the building and heating system have been materially altered. A single local cold room may need a room-specific investigation.

Plan the heat pump as a complete system

Controls work best when heat loss, emitter performance, hydraulics, commissioning and handover have been considered together. Explore AEG’s approach to air source heat pump assessment and installation.

Explore AEG’s air source heat pump service

Technical guidance checked on 11 October 2026. Always follow the manufacturer’s instructions and the settings recorded for the specific installation.